Feed Manufacturing Technology

Home Forums Feed Manufacturing Technology Feed Manufacturing Technology

  • Muhammad Zeeshan Asghar

    Member
    April 1, 2026 at 5:26 am

    Validate mixer efficiency by performing homogeneity tests (e.g., taking multiple representative samples and calculating coefficient of variation (CV) for a tracer or key nutrient); acceptable CV typically <10% (often <5% for critical mixes).
    Also run segregation and discharge tests (fill/empty cycles), visual inspections of mixing time, and compare retained vs. expected concentrations to confirm consistent performance.

  • Md.Mizanor Rahman

    Member
    March 31, 2026 at 12:21 pm

    Vaidate mixer efficieny by taking multiple sample after mixing and analyzing nutrient or additive uniformity

  • Md. Osman Sheikh

    Member
    March 31, 2026 at 9:33 am

    Taking multiple samples from a batch and calculating the Coefficient of Variation (CV).